AO1
- General
- Shall be an established product with
a national and international distribution
network for clients with remote sites.
- Shall offer stackable panel segments
(PolyPanel) which provide versatile
functions such as:
- Segmented-tile appearance
- Ability to repurpose shorter existing
panels
- Reuse as taller panels
- Add new functionality
- Glazed top
- Open frame
- Marker board
- Shall offer factory-based assistance
including
- CAD-based drawing (of furniture)
services at no charge to any dealer
- Drawing, application and purchase
order review before order entry
- Technical assistance
- Shall be approved for sale to General
Services Administration (GSA).
- Panels
General
- Shall offer complete vocabulary of
panel types to create functional work
stations in the broadest range from
task/clerical to semi-private offices,
including
- Hard surface (painted aluminum
skin for maximum durability)
- Fabric covered
- Fabric covered acoustical
- Fabric tackable
- Open frame
- Glazed, with glazing options:
Clear, Smoke, Frosted
- Half-Glazed, with glazing options:
Clear, Smoke, Frosted
- Partial-Glazed, with glazing options:
Clear, Smoke, Frosted
- Door Panel, 36"w-without sidelite
- Door Panel, 48"w-with sidelite
- The panel system must meet the class
A requirements for flame spread and
smoke development as specified by the
National Fire Protection Association
(NFPA) in the 1988 Life Safety Code
No. 101 and the Underwriters Laboratories
requirements for use with energy distribution
components.
- Panels must be UL listed/CSA certified
and labeled.
- Frames shall allow for non-progressive
panel removal or replacement.
- Panel heights shall be a range of
34" high to 80" high
- 34" Window sill height
- 42" Traditional Reception height
- 48" Nominal seated visual privacy
- 56" Full seated visual privacy
- 65" Traditional standing visual
privacy
- 83" Semi-private office height
- Widths shall vary from 12" wide to
60" wide, in traditional architectural
6" modularity, except 18"w and 54"w:
12", 24", 30", 36", 42", 48" and 60".
- Panels must be equipped with adjustable
leveler glides at least 4½" long.
- The panel system must employ a non-progressive
entry system where installation may
begin with any partition in the run.
- Shall include a broad array of fabric
selections and price grade levels (
includes eighty (80) patterns in five
(5) grade/price levels).
- Panels must be less than two inches
thick and lightweight (e.g., one person
can easily maneuver panels of any height,
less than 60 inches wide).
- Panel connection system must be a
self-aligning, metal-to-metal wedge-and-block
system.
- The panel-to-panel and panel-to-connector
joint design shall incorporate an integrated
seal designed to seal out light and
noise transmission through it.
- The system must not have product 'generation'
changes that restrict full integration
of future product with original product
without adapters or modifications. Enhancements
to the original design must be fully
useable with the original generation
(non-obsolesence).
- Panel base raceway must accommodate
a minimum of twenty 25-pair cables in
a powered panel and up to forty 25-pair
cables in non-powered panels.
Hard Surface and Fabric Covered Panels
- Panel frame construction: frame shall
be made of 1.75" thick oriented strand
board (OSB) vertical stiles and horizontal
rails. Core shall be honeycomb construction
of nominal 4½" X 4½" cells made of corrugated
material. Frame bottom inside corners
must be reinforced with added wood blocks
glued-in from the corner to across glide
hole. Frame and core shall be bonded
between two hardboard sheets (aluminum-skinned
for hard surface). Panel faces shall
be uniform in appearance and show no
blisters, tears, waviness, or core telegraphing.
There shall be no delamination. Each
side of the frame shall be completely
covered with upholstery fabric. Panel
top edge shall be completely covered
with a powder coated, extruded aluminum
top cap with a barbed "T" pressed into
a groove machined into the top horizontal
rail. Panel end trim shall be roll-formed
14-gauge cold-rolled steel powder coated
to match the top cap. Enamel-coated
cold rolled steel hanger frames shall
have slots at one-inch increments for
suspension of components. Cast aluminum
wedge blocks shall permit assembly of
panel to adjacent panels, connectors
or end caps with use of appropriate
hardware.
Acoustic, Tackable Panels
- Panel frame construction: same
as above, except
- Acoustic: A layer of acoustic
batting is bonded to the hardboard
surface beneath the surface fabric.
- Tackable: A layer of tackable
compressed fiberglass is bonded
to the hardboard surface beneath
the surface fabric.
Open Frame, Glazed, Half-Glazed, Partial-Glazed,
Door Panels
- Panel frame construction: frame shall
be constructed of welded 18 gauge cold
rolled rectangular steel tubing, 1”
x 1.75” cross section at top and
sides, 1.50” x 1.75” cross
section at bottom, all with powder coat
finish. All welds shall be ground smooth
and flush at joints. Glazing retainer
shall be extruded, rigid polyvinyl chloride
(PVC). Color of retainer shall be color-through
and match that of frame. Glazed sheet
shall be ¼-inch thick acrylic
glazing. Panel top edge shall be completely
covered with a powder coated post-formed,
cold rolled steel top cap adhered with
double-face tape. Panel end trim shall
be roll-formed 14-gauge cold-rolled
steel powder coated to match the frame
and top cap. Enamel-coated cold rolled
steel hanger frames shall have slots
at one-inch increments for suspension
of components. Cast aluminum wedge blocks
shall permit assembly of panel to adjacent
panels, connectors or end caps with
use of appropriate hardware.
- Connectors
- Connectors shall be available to
create the following connections:
- 2-Way 90º
- 3-Way
- 4-Way
- 2-Way 180º Spacing
- Straight Line
- End Cap
- T-Connector
- Wall Strip
General
- Connectors shall have a powder
coated paint finish and include
attachment hardware.
- Connector top caps shall be integrally
colored to match powder coat finish.
2-Way 90° Connector
3-Way Connector
4-Way Connector
2-Way 180° Spacing Connector
- Each connector shall be extruded
aluminum and shall be furnished
with preassembled cast aluminum
draw blocks and socket head screws
for each functional face of the
connector.
- Each connector shall be predrilled
on the vertical sides, permitting
the relocation of the top draw blocks
and the attachment of different
height panels to the connector.
Straight Line Connector
- Draw rod shall be 5/16-inch diameter
steel rod threaded at bottom which
shall fit into an internal threaded
steel coupling in the bottom draw
block
- Draw blocks shall be cast aluminum.
End Cap
- Roll-formed shell shall be 14-gauge
cold-rolled steel. Assembly shall
be provided with cast aluminum draw
blocks and socket head screws.
T-Connector Assembly
- T-connector shall be cold-rolled
steel channel, preassembled with
cast aluminum wedge blocks.
Wall Strip
- Hanger strip casing shall be extruded
aluminum.
- Pre-assembled, cold-rolled steel
hanger insert shall have double
sets of slots at one inch increments.
- Casing shall be anodized. Hanger
insert shall be black-finished.
- Raceway
Covers
- Wire management assemblies, trim
covers and telecommunication poles shall
manage the wires and cables in an unobtrusive,
aesthetic manner, with maximum access
into and out of the wire management
network.
- A wire management assembly shall consist
of a steel base plate with drawn cups
at each end for the panel glides, side
covers, and fillers. Assembly shall
form a continuous trim at the panel
bottom, the full length of the panel
run.
- Side covers shall snap on and off
the base plate for wire access. All
plastic parts shall be of Noryl N190
with textured finish, resistant to common
cleaning materials. A wire management
assembly (with 3½" glide extension)
and appropriate trim cover shall be
capable of concealing sixteen 25-pair
telecommunication cables or eight 100-pair
cables. When used in conjunction with
electrical harnesses, capacities shall
be six 25-pair or four 100-pair telecommunication
cables.
- The wire management assembly shall
provide for total lay-in capabilities
of telecommunication cables.
- Power
Distribution
- Power system must be UL/CUL recognized
under UL 1286 for power distribution.
- Power kit shall provide for distribution
of three, 20-amp electrical circuits
and wire management for panels.
- Power system shall allow continuation
of power through panels which do not
require access to power through duplex
receptacles.
- The base plate shall be made of steel
with drawn cups at each end for the
extended panel glides.
- Side covers shall snap on and off
the base plate for wire access. The
trim covers shall have removable access
hatches for wire entry/exit.
- All plastic parts shall have a textured
finish that is resistant to common cleaning
materials.
- The power system shall have capacity
for two duplex outlets per panel side
(total of four outlets) on all panels
wider than 24 inches.
- The receptacles must be indicated
with a symbol on the face to identify
its line.
- The power system must be modular and
be able to provide power selectively
only at needed locations, and be rearranged
without altering or disassembling the
panel system. Power system must have
access to any circuit via duplex receptacles.
- The power system must offer ceiling
access or end-of-panel access.
- The power system shall be reconfigurable
without the need for an electrician
(unless the reconfiguration involves
the building power source).
- Power distribution shall be non-directional
and unhanded for reconfiguration flexibility.
- Electrical distribution must be shielded
and grounded to provide an effective
EMF barrier.
- Shall have available adapter kits
to provide all necessary components
and assemblies to convert non-powered
panels with wire management to powered
panels.
- Work
Surfaces
- Work surfaces shall be greater than
1" thick, 3-ply/balanced ply construction
consisting of: horizontal-grade high
pressure laminate on solid core, 45
Ib. industrial grade particle board
with phenolic backer.
- Shall offer at least two edge options
and an expanded vocabulary of surface
shapes:
- T-mold (color-through) with 2"
radius corners
- Rectangular
- Corner
- Spanner
- 90º Spanner
- Peninsula
- Transaction
- 3mm matching color-through PVC
edge on all four sides
- Rectangular
- Corner
- Spanner
- 90º Spanner
- Extended corner
- Peninsula
- Extended peninsula
- Teardrop
- Extended Teardrop
- Corner Wedge
- Transaction
- Shall include predrilled holes for
standard support arm locations.
- Shall offer value option laminate
finishes without minimum quantities.
- Shall offer rectilinear and curvilinear
shape options.
- Shall include the following support
options:
- Reinforced cantilever arm
- Shared cantilever arm
- Front/rear support brackets
- Clear access panel
- Structural filing or storage component
- Flat brackets (for work surface-to-work
surface)
- Post leg (single and double)
- C-Leg
- Counter cap support shall be cast
of aluminum alloy.
- Overhead
Storage
- Overhead storage shall have reinforced
bottom shelf, and top for flipper door
units. · Sixteen gauge sheet steel shelf
shall be formed with folded front and
back edges to provide front and rear
rail for installation of accessories.
- Ends shall be made of high compression
or high density molded phenolic particle
board end panels with self edge shall
be equipped with pressed-in, threaded
inserts, pre-assembled with screws.
- Multiple hook, cold-rolled steel hangers
shall be pre-assembled to each end panel
for hook-on installation to slotted
hanger strips. Hangers shall have integral
anti-dislodgement design to prevent
risk of inadvertent disengagement of
a mechanical device.
- Flipper door storage units must be
available ordered separately as shelves
and flipper doors or as a complete unit.
They must be compatible with all panel
widths. Overhead storage units must
be attachable to either panels or walls
(using wall strips) and adjustable vertically
at one-inch increments the entire length
of the panel or wall strips.
- Standard flipper door shall be upholstered.
- Shall offer optional style of overhead
storage, including
- Radius-end all-metal shelf in
two heights
- Flipper door unit-all metal-with
option of receding door or over-the-top
door
- Shelves and flipper door covers shall
be powder coated for maximum scratch
and abrasion resistance.
- Interior height shall be no less than
13" to accommodate domestic and international
(A4) paper/binder formats.
- Recessed bottom shelf to conceal task
light and to maximize clearance between
work surface for office equipment on
work surface.
- Tack boards shall be available 11½
or 15½ inches high. The tack board shall
be constructed of a fiberboard core,
covered with fabric. Hanger clips of
cold-rolled steel should allow attachment
to panel hanger frames or wall strips.
- Standard utility task lights shall
be housed in a formed 20 gauge steel
case with
- UL Listed/CSA certified and labeled
- Polished, UV-stabilized white
vinyl reflector
- Prismatic acrylic lens
- T-8 fluorescent cool white lamp
- Nine-foot long plug cable
- Available sizes appropriate to
the overhead storage unit to which
it is attached
- Filing
& Storage Components
- Shall offer complete range of filing
and storage components including
- Work surface-supporting
- Hanging
- Freestanding
- Mobile
- Lateral File
- Work surface-supporting
- Free-standing
- Bookcase
- Desktop hutch
- Storage cabinet
- Bookcase/pedestal
- Storage tower
- Storage tower/bookcase
- Full-depth pedestals shall be capable
of panel or freestanding applications
and provide work surface-to-floor support
without the need for cosmetic filler
panels or end panels.
- Pedestals shall be available in 22"
and 28" depths.
- All pedestals shall have
- Flush-mounted drawer fronts with
full width recessed pulls
- Drawers shall be five-sided construction
- Four (4) leveling glides
- Drawers shall be constructed using
16 gauge (fronts) and 20 gauge (case)
steel
- All box and file drawers shall
have full extension steel ball bearing
slides
- 30" deep file drawers shall accommodate
two (2) rows of letter-sized files
side-by-side
- All storage components shall have
a powder coat finish.
- Lateral file units shall be available
with 2, 3, 4 or 5 drawers and 30, 36
or 42 inches wide.
- Lateral files shall incorporate a
positive interlock system, allowing
only one drawer to be opened at a time.
- File drawers shall have integral hanging
folder lip and support to hold letter,
legal and A-4 size paper.
- Shall include removable pencil tray
for box drawers.
- Shall have available optional box
drawer divider.
- Core removable locks shall be standard
for all storage components.
- Keyed-alike option shall be available
as well as a 'master' key.
- Accessories
- Shall offer full array of productivity
tools, including
- Pencil drawer
- Keyboard tray
- Task light
- Coat hook
- Tack board
- Tool rail & accessories
- File top cushion for mobile pedestals
- Shall include a full-featured ergonomic
keyboard option including
- 360-degree swivel
- Minimum 6" height range
- Plaltform tilt with 5-degree negative
tilt
- Integrated palm rest for adequate
wrist support
- Warranty
Compatico "Customer First Service"
warranties its products to be free from
defects in material and workmanship for
a period of (10) years from the date of
initial delivery. This warranty is not transferable
and is only given to the original purchaser.
Exceptions to the initial 10-year warranty
are as follows:
Fabric: Compatico fabric grades 1.2, and
3 have a 3-year warranty period.
Fabric: All COM fabrics (fabrics specified
and purchased by buyer) that are not standard
grades 1, 2, and 3 Compatico fabrics are
not warranted.
Electrical: Compatico electrical products
have a 5-year warranty period.
This warranty made by Compatico is only
to original purchaser acquiring the product
directly from Compatico, its authorized
dealers, or others who are specifically
authorized by Compatico to sell such products.
Compatico's obligation and the purchaser's
remedy pursuant to this warranty are : limited
to repair or replacement, at Compatico's
option, FOB Compatico's headquarters, of
replacement parts which prove, under normal
use, to be defective within the period stated,
which remedy is expressly agreed to be exclusive
as a condition of such replacement. No person,
firm, or corporation is authorized to assume
for Compatico any other liability in connection
with COMPATICO products. Customer will get
credit for returns only after received by
COMPATICO and must be returned in 30 days.
THERE ARE NO WARRANTIES EXCEPT AS EXPRESSLY
SET FORTH ABOVE, EITHER EXPRESSED OR IMPLIED,
INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR ANY PARTICULAR PURPOSE. COMPATICO'S
LIABILITY WITH RESPECT TO ITS PRODUCTS SHALL
NOT EXCEED THAT EXPRESSLY SET FORTH ABOVE
IRRESPECTIVE OF THE THEORY UPON WHICH ANY
CLAIM MIGHT BE BASED INCLUDING BREACH OF
CONTRACT, WARRANTY. NEGLIGENCE, OR STRICT
LIABILITY ON TORT. UNDER NO CIRCUMSTANCES
SHALL COMPATICO BE LIABLE FOR SPECIAL INCIDENTAL,
OR CONSEQUENTIAL DAMAGES.
This warranty does not apply to damages
resulting from shipment, storage, accident,
alteration, misuse, assembly or installation.
All claims under this warranty must be authorized
in writing by COMPATICO prior to the repair
or replacement of products.
AO2
- General
- Shall be an established product with
a national and international distribution
network for clients with remote sites.
- Shall offer stackable panel segments
(PolyPanel) which provide versatile
functions such as:
- Segmented-tile appearance
- Ability to repurpose shorter existing
panels
- Reuse as taller panels
- Add new functionality
- Glazed top
- Open frame
- Marker board
- Shall offer factory-based assistance
including
- CAD-based drawing (of furniture)
services at no charge to any dealer
- Drawing, application and purchase
order review before order entry
- Technical assistance
- Shall be approved for sale to General
Services Administration (GSA).
- Panels
General
- Shall offer complete vocabulary of
panel types to create functional work
stations in the broadest range from
task/clerical to semi-private offices,
including
- Hard surface (painted aluminum
skin for maximum durability)
- Fabric covered
- Fabric covered acoustical
- Fabric tackable
- Open frame
- Glazed, with glazing options:
Clear, Smoke, Frosted
- Half-Glazed, with glazing options:
Clear, Smoke, Frosted
- Partial-Glazed, with glazing options:
Clear, Smoke, Frosted
- Door Panel, 36"w-without sidelite
- Door Panel, 48"w-with sidelite
- The panel system must meet the class
A requirements for flame spread and
smoke development as specified by the
National Fire Protection Association
(NFPA) in the 1988 Life Safety Code
No. 101 and the Underwriters Laboratories
requirements for use with energy distribution
components.
- Panels must be UL listed/CSA certified
and labeled.
- Panels shall have a 5”h wire
management raceway specifiable as powered
or non-powered. If powered, it is to
ship with the power assembly installed.
Raceway covers are to be hingeable and
removable for ease in laying in telecom
cables .
- Frames shall allow for non-progressive
panel removal or replacement.
- Panel heights shall be a range of
34" high to 80" high
- 34" Window sill height
- 42" Traditional Reception height
- 48" Nominal seated visual privacy
- 56" Full seated visual privacy
- 65" Traditional standing visual
privacy
- 83" Semi-private office height
- Widths shall vary from 12" wide to
60" wide, in traditional architectural
6" modularity, except 18"w and 54"w:
12", 24", 30", 36", 42", 48" and 60".
- Panels must be equipped with adjustable
leveler glides at least 4½" long.
- The panel system must employ a non-progressive
entry system where installation may
begin with any partition in the run.
- Shall include a broad array of fabric
selections and price grade levels (
includes eighty (80) patterns in five
(5) grade/price levels).
- Panels must be less than two inches
thick and lightweight (e.g., one person
can easily maneuver panels of any height,
less than 60 inches wide).
- Panel connection system must be a
self-aligning, metal-to-metal wedge-and-block
system.
- The panel-to-panel and panel-to-connector
joint design shall incorporate an integrated
seal designed to seal out light and
noise transmission through it.
- The system must not have product 'generation'
changes that restrict full integration
of future product with original product
without adapters or modifications. Enhancements
to the original design must be fully
useable with the original generation
(non-obsolesence).
- Panel base raceway must accommodate
a minimum of twenty 25-pair cables in
a powered panel and up to forty 25-pair
cables in non-powered panels.
Hard Surface and Fabric Covered Panels
- Panel frame construction: frame shall
be made of 1.75" thick oriented strand
board (OSB) vertical stiles and horizontal
rails. Core shall be honeycomb construction
of nominal 4½" X 4½" cells made of corrugated
material. Frame bottom inside corners
must be reinforced with added wood blocks
glued-in from the corner to across glide
hole. Frame and core shall be bonded
between two hardboard sheets (aluminum-skinned
for hard surface). Panel faces shall
be uniform in appearance and show no
blisters, tears, waviness, or core telegraphing.
There shall be no delamination. Each
side of the frame shall be completely
covered with upholstery fabric. Panel
top edge shall be completely covered
with a powder coated, extruded aluminum
top cap with a barbed "T" pressed into
a groove machined into the top horizontal
rail. Panel end trim shall be roll-formed
14-gauge cold-rolled steel powder coated
to match the top cap. Enamel-coated
cold rolled steel hanger frames shall
have slots at one-inch increments for
suspension of components. Cast aluminum
wedge blocks shall permit assembly of
panel to adjacent panels, connectors
or end caps with use of appropriate
hardware.
Acoustic, Tackable Panels
- Panel frame construction: same
as above, except
- Acoustic: A layer of acoustic
batting is bonded to the hardboard
surface beneath the surface fabric.
- Tackable: A layer of tackable
compressed fiberglass is bonded
to the hardboard surface beneath
the surface fabric.
Open Frame, Glazed, Half-Glazed, Partial-Glazed,
Door Panels
- Panel frame construction: frame shall
be constructed of welded 18 gauge cold
rolled rectangular steel tubing, 1”
x 1.75” cross section at top and
sides, 1.50” x 1.75” cross
section at bottom, all with powder coat
finish. All welds shall be ground smooth
and flush at joints. Glazing retainer
shall be extruded, rigid polyvinyl chloride
(PVC). Color of retainer shall be color-through
and match that of frame. Glazed sheet
shall be ¼-inch thick acrylic
glazing. Panel top edge shall be completely
covered with a powder coated post-formed,
cold rolled steel top cap adhered with
double-face tape. Panel end trim shall
be roll-formed 14-gauge cold-rolled
steel powder coated to match the frame
and top cap. Enamel-coated cold rolled
steel hanger frames shall have slots
at one-inch increments for suspension
of components. Cast aluminum wedge blocks
shall permit assembly of panel to adjacent
panels, connectors or end caps with
use of appropriate hardware.
- Connectors
- Connectors shall be available to
create the following connections:
- 2-Way 90º
- 3-Way
- 4-Way
- 2-Way 180º Spacing
- Straight Line
- End Cap
- T-Connector
- Wall Strip
General
- Connectors shall have a powder
coated paint finish and include
attachment hardware.
- Connector top caps shall be integrally
colored to match powder coat finish.
2-Way 90° Connector
3-Way Connector
4-Way Connector
2-Way 180° Spacing Connector
- Each connector shall be extruded
aluminum and shall be furnished
with preassembled cast aluminum
draw blocks and socket head screws
for each functional face of the
connector.
- Each connector shall be predrilled
on the vertical sides, permitting
the relocation of the top draw blocks
and the attachment of different
height panels to the connector.
Straight Line Connector
- Draw rod shall be 5/16-inch diameter
steel rod threaded at bottom which
shall fit into an internal threaded
steel coupling in the bottom draw
block
- Draw blocks shall be cast aluminum.
End Cap
- Roll-formed shell shall be 14-gauge
cold-rolled steel. Assembly shall
be provided with cast aluminum draw
blocks and socket head screws.
T-Connector Assembly
- T-connector shall be cold-rolled
steel channel, preassembled with
cast aluminum wedge blocks.
Wall Strip
- Hanger strip casing shall be extruded
aluminum.
- Pre-assembled, cold-rolled steel
hanger insert shall have double
sets of slots at one inch increments.
- Casing shall be anodized. Hanger
insert shall be black-finished.
- Raceway
Covers
- Wire management assemblies, trim
covers and telecommunication poles shall
manage the wires and cables in an unobtrusive,
aesthetic manner, with maximum access
into and out of the wire management
network.
- A wire management assembly shall consist
of a steel frame attached to the panel
frame and include a leveling glide at
each end. Raceway covers shall have
flexible 'skirt' ends for concealing
telecom cable ingress/egress between
panels. Assembly shall form a continuous
trim at the panel bottom, the full length
of the panel run.
- Side covers shall be hingeable and
snap on and off the base frame for wire
access. All plastic parts shall be of
Noryl N190 with textured finish, resistant
to common cleaning materials.
- A wire management assembly with trim
cover shall be capable of concealing
sixteen 25-pair telecommunication cables
or eight 100-pair cables. When used
in conjunction with electrical harnesses,
capacities shall be six 25-pair or four
100-pair telecommunication cables.
- Power
Distribution
- Power system must be UL/CUL recognized
under UL 1286 for power distribution.
- Power kit shall provide for distribution
of four, 15-amp electrical circuits
and wire management for panels; three
general circuits and one isolated/dedicated
circuit.
- Power system shall allow continuation
of power through panels which do not
require access to power through duplex
receptacles.
- The base plate shall be made of steel
with drawn cups at each end for the
extended panel glides.
- Side covers shall snap on and off
the base plate for wire access.
- All plastic parts shall have a textured
finish that is resistant to common cleaning
materials.
- The power system shall have capacity
for two duplex outlets per panel side
(total of four outlets) on all panels
wider than 24 inches.
- The receptacles must be indicated
with a symbol on the face to identify
its line.
- The power system shall be modular
and provide power selectively only at
needed locations. It shall also be reconfigurable
without tools, without altering or disassembling
the panel system or without the need
for an electrician (unless the reconfiguration
involves the building power source).
- Power system must have access to any
circuit via duplex receptacles.
- The power system must offer ceiling
access or end-of-panel access.
- Power distribution shall be non-directional
and unhanded for reconfiguration flexibility.
- Electrical distribution must be shielded
and grounded to provide an effective
EMF barrier.
- Shall have available adapter kits
to provide all necessary components
and assemblies to convert non-powered
panels with wire management to powered
panels.
- Work
Surfaces
- Work surfaces shall be greater than
1" thick, 3-ply/balanced ply construction
consisting of: horizontal-grade high
pressure laminate on solid core, 45
Ib. industrial grade particle board
with phenolic backer.
- Shall offer at least two edge options
and an expanded vocabulary of surface
shapes:
- T-mold (color-through) with 2"
radius corners
- Rectangular
- Corner
- Spanner
- 90º Spanner
- Peninsula
- Transaction
- 3mm matching color-through PVC
edge on all four sides
- Rectangular
- Corner
- Spanner
- 90º Spanner
- Extended corner
- Peninsula
- Extended peninsula
- Teardrop
- Extended Teardrop
- Corner Wedge
- Transaction
- Shall include predrilled holes for
standard support arm locations.
- Shall offer value option laminate
finishes without minimum quantities.
- Shall offer rectilinear and curvilinear
shape options.
- Shall include the following support
options:
- Reinforced cantilever arm
- Shared cantilever arm
- Front/rear support brackets
- Clear access panel
- Structural filing or storage component
- Flat brackets (for work surface-to-work
surface)
- Post leg (single and double)
- C-Leg
- Counter cap support shall be cast
of aluminum alloy.
- Overhead
Storage
- Overhead storage shall have reinforced
bottom shelf, and top for flipper door
units. · Sixteen gauge sheet steel shelf
shall be formed with folded front and
back edges to provide front and rear
rail for installation of accessories.
- Ends shall be made of high compression
or high density molded phenolic particle
board end panels with self edge shall
be equipped with pressed-in, threaded
inserts, pre-assembled with screws.
- Multiple hook, cold-rolled steel hangers
shall be pre-assembled to each end panel
for hook-on installation to slotted
hanger strips. Hangers shall have integral
anti-dislodgement design to prevent
risk of inadvertent disengagement of
a mechanical device.
- Flipper door storage units must be
available ordered separately as shelves
and flipper doors or as a complete unit.
They must be compatible with all panel
widths. Overhead storage units must
be attachable to either panels or walls
(using wall strips) and adjustable vertically
at one-inch increments the entire length
of the panel or wall strips.
- Standard flipper door shall be upholstered.
- Shall offer optional style of overhead
storage, including
- Radius-end all-metal shelf in
two heights
- Flipper door unit-all metal-with
option of receding door or over-the-top
door
- Shelves and flipper door covers shall
be powder coated for maximum scratch
and abrasion resistance.
- Interior height shall be no less than
13" to accommodate domestic and international
(A4) paper/binder formats.
- Recessed bottom shelf to conceal task
light and to maximize clearance between
work surface for office equipment on
work surface.
- Tack boards shall be available 11½
or 15½ inches high. The tack board shall
be constructed of a fiberboard core,
covered with fabric. Hanger clips of
cold-rolled steel should allow attachment
to panel hanger frames or wall strips.
- Standard utility task lights shall
be housed in a formed 20 gauge steel
case with
- UL Listed/CSA certified and labeled
- Polished, UV-stabilized white
vinyl reflector
- Prismatic acrylic lens
- T-8 fluorescent cool white lamp
- Nine-foot long plug cable
- Available sizes appropriate to
the overhead storage unit to which
it is attached
- Filing
& Storage Components
- Shall offer complete range of filing
and storage components including
- Work surface-supporting
- Hanging
- Freestanding
- Mobile
- Lateral File
- Work surface-supporting
- Free-standing
- Bookcase
- Desktop hutch
- Storage cabinet
- Bookcase/pedestal
- Storage tower
- Storage tower/bookcase
- Full-depth pedestals shall be capable
of panel or freestanding applications
and provide work surface-to-floor support
without the need for cosmetic filler
panels or end panels.
- Pedestals shall be available in 22"
and 28" depths.
- All pedestals shall have
- Flush-mounted drawer fronts with
full width recessed pulls
- Drawers shall be five-sided construction
- Four (4) leveling glides
- Drawers shall be constructed using
16 gauge (fronts) and 20 gauge (case)
steel
- All box and file drawers shall
have full extension steel ball bearing
slides
- 30" deep file drawers shall accommodate
two (2) rows of letter-sized files
side-by-side
- All storage components shall have
a powder coat finish.
- Lateral file units shall be available
with 2, 3, 4 or 5 drawers and 30, 36
or 42 inches wide.
- Lateral files shall incorporate a
positive interlock system, allowing
only one drawer to be opened at a time.
- File drawers shall have integral hanging
folder lip and support to hold letter,
legal and A-4 size paper.
- Shall include removable pencil tray
for box drawers.
- Shall have available optional box
drawer divider.
- Core removable locks shall be standard
for all storage components.
- Keyed-alike option shall be available
as well as a 'master' key.
- Accessories
- Shall offer full array of productivity
tools, including
- Pencil drawer
- Keyboard tray
- Task light
- Coat hook
- Tack board
- Tool rail & accessories
- File top cushion for mobile pedestals
- Shall include a full-featured ergonomic
keyboard option including
- 360-degree swivel
- Minimum 6" height range
- Plaltform tilt with 5-degree negative
tilt
- Integrated palm rest for adequate
wrist support
- Warranty
Compatico "Customer First Service"
warranties its products to be free from
defects in material and workmanship for
a period of (10) years from the date of
initial delivery. This warranty is not transferable
and is only given to the original purchaser.
Exceptions to the initial 10-year warranty
are as follows:
Fabric: Compatico fabric grades 1.2, and
3 have a 3-year warranty period.
Fabric: All COM fabrics (fabrics specified
and purchased by buyer) that are not standard
grades 1, 2, and 3 Compatico fabrics are
not warranted.
Electrical: Compatico electrical products
have a 5-year warranty period.
This warranty made by Compatico is only
to original purchaser acquiring the product
directly from Compatico, its authorized
dealers, or others who are specifically
authorized by Compatico to sell such products.
Compatico's obligation and the purchaser's
remedy pursuant to this warranty are : limited
to repair or replacement, at Compatico's
option, FOB Compatico's headquarters, of
replacement parts which prove, under normal
use, to be defective within the period stated,
which remedy is expressly agreed to be exclusive
as a condition of such replacement. No person,
firm, or corporation is authorized to assume
for Compatico any other liability in connection
with COMPATICO products. Customer will get
credit for returns only after received by
COMPATICO and must be returned in 30 days.
THERE ARE NO WARRANTIES EXCEPT AS EXPRESSLY
SET FORTH ABOVE, EITHER EXPRESSED OR IMPLIED,
INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR ANY PARTICULAR PURPOSE. COMPATICO'S
LIABILITY WITH RESPECT TO ITS PRODUCTS SHALL
NOT EXCEED THAT EXPRESSLY SET FORTH ABOVE
IRRESPECTIVE OF THE THEORY UPON WHICH ANY
CLAIM MIGHT BE BASED INCLUDING BREACH OF
CONTRACT, WARRANTY. NEGLIGENCE, OR STRICT
LIABILITY ON TORT. UNDER NO CIRCUMSTANCES
SHALL COMPATICO BE LIABLE FOR SPECIAL INCIDENTAL,
OR CONSEQUENTIAL DAMAGES.
This warranty does not apply to damages
resulting from shipment, storage, accident,
alteration, misuse, assembly or installation.
All claims under this warranty must be authorized
in writing by COMPATICO prior to the repair
or replacement of products.
|
|
|
|
|
|
©Copyright
2007 Harco Moving and Installation All Rights Reserved. |
|
|